
تعداد نشریات | 41 |
تعداد شمارهها | 1,156 |
تعداد مقالات | 9,939 |
تعداد مشاهده مقاله | 18,551,372 |
تعداد دریافت فایل اصل مقاله | 12,865,405 |
Development of Homogeneous Liquid-Liquid Microextraction via Flotation Assistance Method for Determination of Benzene, Toluene, Xylene and Styrene in Water Samples | ||
Iranian Journal of Analytical Chemistry | ||
مقاله 6، دوره 1، شماره 1، خرداد 2014، صفحه 20-28 اصل مقاله (1.04 M) | ||
نوع مقاله: Full research article | ||
نویسندگان | ||
Majid Haji Hosseini* 1؛ Mohammad Reza Rezaei2؛ Mohammad Rezaee1؛ Peyman Asaadi2؛ Khatereh Ashtari2 | ||
1Nuclear Fuel Cycle Research School, Nuclear Science & Technology Research, Atomic Energy Organization of Iran, Tehran, Iran | ||
2Departmant of Chemistry , Azad University of Saveh , Saveh ,Iran | ||
چکیده | ||
This study propose a new analytical protocol for the determination of benzene, xylene, toluene and styrene in water samples using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) technique followed by gas chromatography-mass spectrometry (GC-MS). In this research, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added into the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. The effects of different variables on the efficiency of the extraction were studied simultaneously using experimental design. Response surface methodology was applied to investigation the optimum conditions of each variable. Using optimized variables in the extraction process, for all target analytes, the detection limits, the precisions and the linearity of the method were found in the range of 0.8-8.2 ng mL-1, 3.09-7.96% (RSD, n=4) and 1-100 ng mL-1, respectively. The headspace method was used for the accuracy of comparison. The performance of the method was evaluated for extraction and determination of analytes in water samples and satisfactory results were obtained (RSD ≤10.06 %). | ||
کلیدواژهها | ||
Homogeneous liquid-liquid microextraction؛ Flotation assistance؛ BTEX؛ Gas chromatography؛ Mass spectrometry؛ Water Samples | ||
عنوان مقاله [English] | ||
استفاده از روش میکرواستخراج با حلال بر پایه هموژناسیون – فلوتاسیون به منظور اندازهگیری بنزن، تولوئن، زایلن و استایرن در نمونههای آبی | ||
نویسندگان [English] | ||
مجید حاجی حسینی1؛ محمد رضا رضایی2؛ محمد رضایی1؛ پیمان اسعدی2؛ خاطره اشتری2 | ||
1تهران، انتهای کارگر شمالی، سازمان انرژی اتمی ایران، پژوهشگاه علوم و فنون هسته ای، پژوهشکده سوخت هسته ای، صندوق پستی: 8486-11365 | ||
2بخش شیمیٍ دانشگاه آزاد اسلامی واحد ساوهُ ساوه ایران | ||
چکیده [English] | ||
در کار حاضر روش آمادهسازی جدیدی برای اندازهگیری بنزن، تولوئن، زایلن و استایرن توسط دستگاه GC/MS در نمونههای آبی به طریق میکرواستخراج مایع-مایع بر پایه هموژناسیون–فلوتاسیون (HLLME-FA) معرفی گردیده است. در این روش استفاده از یک سل استخراجی مخصوص نیاز به سانتریفوژ جهت جداکردن فازهای آلی و آبی را از بین میبرد.روش حاضر با موفقیت جهت شناسایی و استخراج BTEX در نمونههای حقیقی به کار برده شد. | ||
آمار تعداد مشاهده مقاله: 3,393 تعداد دریافت فایل اصل مقاله: 3,782 |