Sol-gel Approach for Fabrication of Solid-Phase Microextraction Hollow Fiber: An Efficient Adsorbent for Enrichment of Trace Levels of Antidepressant Drug, Fluoxetine | ||
Iranian Journal of Analytical Chemistry | ||
مقاله 6، دوره 2، شماره 1، خرداد 2015، صفحه 43-49 اصل مقاله (392.78 K) | ||
نوع مقاله: Full research article | ||
نویسندگان | ||
Zarrin Es’haghi* 1؛ Zohreh Rezaeifar2 | ||
1Department of Chemistry, Payame Noor University, P.O. Box 19395-4697, Tehran, I.R. Iran | ||
2Department of Chemistry, Payame Noor University, P.O. Box 19395-4697, Tehran, I.R. Iran | ||
چکیده | ||
This research is on the improvement of the procedure to determination of trace levels of antidepressant drug; fluoxetine in wastewaters. In this research a silica based sol-gel was applied for the extraction of fluoxetine from water samples. This two-phase technique is consisting of aqueous samples of fluoxetine (donor phase) and silica based nanocomposite prepared by sol-gel technique (acceptor phase). Accepter phase was held in the pores and lumen of polypropylene hollow fiber segment. Microextraction experiments were carried out in two steps; extraction from analyte samples by sorbent which is held into the hollow fiber segment and desorption of drug from hallow fiber by using of methanol. Desorbed analyte in order to measurement were offered to HPLC and UV-V is spectrophotometer for further analysis. This method is simple, fast and adopted by a majority of the instrumental methods. Extraction parameters such as sol-gel aging time, pH of donor phase, volume of donor phase, extraction time, stirring rate and effect of surfactant were investigated and optimized. The measurements were done under the optimal conditions. This technique has many advantages, such as the short extraction time, low consumption of organic solvents, elimination of carry-over effect, low limit of detection and high pre-concentration factor. The pre-concentration factor and limit of detection have been gained 3227 and 0.53 ng mL-1, respectively. The linear range and relative standard deviation are 1.0-10000.0 ng mL-1 and 4.8% (n=3), respectively. | ||
کلیدواژهها | ||
Fluoxetine؛ Solid Phase Microextraction؛ sol-gel؛ hollow fiber | ||
عنوان مقاله [English] | ||
نگرش سل-ژل برای ساخت فیبر توخالی میکرواستخراج فاز جامد: یک جاذب کارآمد برای غنی سازی سطوح کم داروی ضد افسردگی فلوکسیتین | ||
نویسندگان [English] | ||
زرین اسحاقی1؛ زهره رضایی فر2 | ||
1بخش شیمی، دانشگاه پیام نور، صندوق پستی 3697-19395، تهران، ایران | ||
2بخش شیمی، دانشگاه پیام نور، صندوق پستی 3697-19395، تهران، ایران | ||
چکیده [English] | ||
این تحقیق عبارتست از توسعه دستورالعملی برای تعیین مقادیر کم داروی فلوکسیتین در نمونه های آبی. روش بر پایه استفاده از جاذب سیلیکای بر پایه سل-ژل می باشد که برای استخراج این دارو از نمونه های آبی به کار رفته است. روش استخراج هم، استفاده از میکرواستخراج فاز جامد فیبر توخالی می باشد. تحت شرایط بهینه فاکتور پیش تغلیظ و حد تشخیص بدست آمده عبارتند از 3227 و 53/0 نانوگرم بر میلی لیتر. رنج خطی عیارت بود از 0/1 تا 0/10000 نانوگرم بر میلی لیتر و تکرار پذیری نیز بر مبنای درصد انحراف استاندارد نسبی 8/4 درصد بدست آمد. | ||