Spectrophotometric Determination of Nalidixic Acid in Some Real Samples After Preconcentration with GO/ZnO Nanocomposite-Based Pipette Tip Micro-Solid Phase Microextraction | ||
Iranian Journal of Analytical Chemistry | ||
مقاله 3، دوره 7، شماره 1 - شماره پیاپی 13، خرداد 2020، صفحه 21-29 اصل مقاله (794.69 K) | ||
نوع مقاله: Full research article | ||
شناسه دیجیتال (DOI): 10.30473/ijac.2019.49189.1157 | ||
نویسندگان | ||
Sayyed Hossein Hashemi* 1؛ Fateme Keykha2 | ||
1Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, P.O. Box 98617-85553, Chabahar, Iran. | ||
2Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, P.O. Box 98617-85553, Chabahar, Iran | ||
چکیده | ||
In this research a graphene oxide/zinc oxide nanocomposite (GO/ZnO) was synthesized and employed for simple and sensitive pipette tip-based micro-solid phase extraction (PT-µSPE) of nalidixic acid (NA) from seawater and human blood plasma samples following by its determination by spectrophotometry. Several parameters affecting the suggested protocol were optimized, namely type and volume of eluent, amount of sorbent, sample volume, number of cycles of extraction and elution, pH of sample solution and type and amount of salt. The optimization performed by both response surface methodology (RSM) and one-variable-at-a-time techniques. Figures of merit were achieved as: detection limit; 0.30 µg L-1, enrichment factor 40 for NA, linear calibration curve in the range of 1.0-200.0 µg L-1; and reproducibility (as RSD %) better than 4.4%. Results for the application of the technique in seawater and human blood plasma showed that this analysis method can be applied for the determination of the analyte in complex real samples successfully. | ||
کلیدواژهها | ||
Nalidixic Acid؛ Seawater؛ Graphene Oxide/Zinc Oxide Nanocomposite؛ Pipette Tip Solid Phase Extraction؛ Response Surface Methodology | ||
عنوان مقاله [English] | ||
تعیین اسپکتروفتومتری نالیدیکسیک اسید در برخی نمونههای حقیقی بعد از پیشتغلیظ با استخراج فاز جامد در سرسمپلر به کمک جاذب نانوکامپوزیت گرافن اکسید/ روی اکسید | ||
نویسندگان [English] | ||
سید حسین هاشمی1؛ فاطمه کیخا2 | ||
1گروه شیمی دریا، دانشکده علوم دریایی، دانشگاه دریانوردی و علوم دریایی، چابهار، ایران | ||
2گروه شیمی دریا، دانشکده علوم دریایی، دانشگاه دریانوردی و علوم دریایی، چابهار، ایران | ||
چکیده [English] | ||
در این کار تحقیقاتی یک نانو کامپوزیت گرافن اکسید/ روی اکسید (GO/ZnO) سنتز گردید و برای استخراج فاز جامد در سر سمپلر نالیدیکسیک اسید از نمونههای آب دریا و پلاسمای خون انسان و تعیین آن با اسپکتروفتومتری بکار رفت. پارامترهای مؤثر بر روش پیشنهادی، از جمله نوع و حجم حلال شوینده، مقدار جاذب، حجم نمونه، تعداد سیکلهای استخراج و شویش، pH محلول نمونه، نوع و مقدار نمک بررسی و بهینه سازی شدند. بهینهسازی با استفاده از روشهای یک متغیر در یک زمان و سطح پاسخ انجام گردید. ارقام شایستگی روش به صورت زیر بدست آمد: حدّ تشخیص روش 30/0 میکروگرم بر لیتر، فاکتور پیشتغلیظ 40 برای NA، محدودة خطّی منحنی درجه بندی 0/200- 0/1 میکروگرم بر لیتر و با تکرارپذیری (RSD) بهتر از 4/4% حاصل گردید. نتایج کاربرد روش در آب دریا و پلاسما خون انسان نشان داد که این روش تجزیهای میتواند برای تعیین آنالیت در نمونههای واقعی پیچیده به طور موفقیت آمیزی بکار رود. | ||
کلیدواژهها [English] | ||
نالیدیکسیک اسید, آب دریا, گرافن اکسید/ روی اکسید, استخراج فاز جامد در سرسمپلر, روششناسی سطح پاسخ | ||
مراجع | ||
[1] A. Khataee, R. Lotfi, A. Hasanzadeh, M. Iranifam and S.W. Joo, A flow injection chemiluminescence method for determination of nalidixic acid based on KMnO4-morin sensitized with CdS quantum dots, Spectrochim. Acta A Mol. Biomol. Spectrosc. 154 (2016) 243-251.
[2] A. Guiberteau, T. Galeano Dıaz, M.I. Rodrıguez Cáceres, J.M. Ortiz Burguillos, I. Durán Merás, F. Salinas López, Polarography and artificial neural network for the simultaneous determination of nalidixic acid and its main metabolite (7-hydroxymethylnalidixic acid), Talanta 62 (2004) 357–365.
[3] A. Guiberteau Cabanillas, M. Rodriguez Caceres, M. Canas, J. Burguillos and T. Galeano Diaz, Square wave adsorptive stripping voltametric determination of the mixture of nalidixic acid and its main metabolite (7-hydroxymethylnalidixic acid) by multivariate methods and artificial neural network, Talanta 72 (2007) 932-940.
[4] L. Capitan-Vallvey, O.M. Al-Barbarawi, M. Fernandez-Ramos, R. Avidad and V.R. Gonzalez, Single-use phosphorimetric sensor for the determinationof nalidixic acid in human urine and milk, Analyst 125 (2000) 2000-2005.
[5] H. Hashemi, M. Khajeh and M. Kaykhaii, Molecularly imprinted stir bar sorptive extraction coupled with atomic absorption spectrometry for trace analysis of copper in drinking water samples, Anal. Methods 5 (2013) 2778-2783.
[6] E. Turiel, G. Bordin and A.R. Rodriguez, Trace enrichment of (fluoro) quinolone antibiotics in surface waters by solid-phase extraction and their determination by liquid chromatography–ultraviolet detection, J. Chromatogr. A 1008 (2003) 145–155.
[7] R. Mirzajani, F. Kardani and Z. Ramezani, Preparation and characterization of magnetic metal–organic framework nanocomposite as solid-phase microextraction fibers coupled with high-performance liquid chromatography for determination of non-steroidal anti-inflammatory drugs in biological fluids and tablet formulation samples, Microchem. J. 144 (2019) 270-284.
[8] M.M. Parrilla Vázquez, P. Parrilla Vázquez, M. Martínez Galera and M.D. Gil Garcia, Determination of eight fluoroquinolones in groundwater samples with ultrasound-assisted ionic liquid dispersive liquid–liquid microextraction prior to high-performance liquid chromatography and fluorescence detection, Anal. Chim. Acta 748 (2012) 20-27.
[9] L. Chen, X. Zhang, Y. Xu, X. Du, X. Sun, L. Sun, H. Wang, Q. Zhao, A. Yu, H. Zhang and L. Ding, Determination of fluoroquinolone antibiotics in environmental water samples based on magnetic molecularly imprinted polymer extraction followed by liquid chromatography-tandem mass spectrometry, Anal. Chim. Acta 662 (2010) 31–38.
[10] M. Hosseini, N. Dalali, A. Karimi, K. Dastanra, Solid phase extraction of copper, nickel, and cobalt in water samples using surfactant coated alumina modified with indane-1,2,3-trione 1,2-dioxime and determination by flame atomic absorption spectrometry, Turk. J. Chem. 34 (2010) 805 – 814.
[11] S.H. Hashemi, H. Yahyavi, M. Kaykhaii, M. Hashemi, M. Mirmoghaddam, A.J. Keikha, Spectrofluorometrical determination of vitamin B1 in different matrices using Box-Behnken designed pipette tip solid phase extraction by a carbon nanotube sorbent, Chem. Select 4 (2019) 3052-3057.
[12] S.H. Hashemi, M. Kaykhaii, A.J. Keikha and E. Mirmoradzehi, Box-Behnken design optimization of pipette tip solid phase extraction for methyl orange and acid red determination by spectrophotometry in seawater samples using graphite based magnetic NiFe2O4 decorated exfoliated as sorbent, Spectrochim. Acta A Mol. Biomol. Spectrosc. 213 (2019) 218-227.S.H.
[13] Hashemi, M. Kaykhaii, A.J. Keikha and Z. Sajjadi, Application of Box-Behnken design in response surface methodology for the molecularly imprinted polymer pipette-tip solid phase extraction of methyl red from seawater samples and its determination by spectrophotometery, Marine Poll. Bull. 137 (2018) 306–314.
[14] S.H. Hashemi, M. Kaykhaii, A.J. Keikha, A. Parkaz, Application of Box–Behnken design in the optimization of a simple graphene oxide/zinc oxide nanocomposite-based pipette tip micro-solid phase extraction for the determination of Rhodamine B and Malachite green in seawater samples by spectrophotometry, Anal. Methods 10 (2018) 5707-5714.
[15] S.H. Hashemi, M. Kaykhaii, A.J. Keikha, Z. Sajjadi and M. Mirmoghaddam, Application of response surface methodology for silver nanoparticle stir bar sorptive extraction of heavy metals from drinking water samples: a Box-Behnken design, Analyst 144 (2019) 3525-3532.
[16] S.H. Hashemi, M. Kaykhaii, A.J. Keikha, E. Mirmoradzehi and G. Sargazi, Application of response surface methodology for optimization of metal– organic framework based pipette‑tip solid phase extraction of organic dyes from seawater and their determination with HPLC, BMC Chem. 13 (2019) 59-69.
[17] S.H. Hashemi, M. Kaykhaii, A.J. Keikha and A. Parkaz, Application of response surface methodology to optimize pipette tip micro-solid phase extraction of dyes from seawater by molecularly imprinted polymer and their determination by HPLC, J. Iran Chem. Soc. (2019) 1-15.
[18] N. Zhang and B. Hu, Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection, Anal. Chim. Acta 723 (2012) 54-60.
[19] J. Lovrić, M. Mesić, M. Macan, M. Koprivanac, M. Kelava and V. Bradamante, Measurement of malondialdehyde (MDA) level in rat plasma after simvastatin treatment using two different analytical methods, Period. Biol. 110 (2008) 63-68.
[20] G. Cuisinaud, N. Ferry, M. Seccia, N. Bernard and J. Sassard, Determination of nalidixic acid and its two major metabolites in human plasma and urine by reversed-phase high-performance liquid chromatography, J. Chromatogr. B 181 (1980) 399-406. | ||
آمار تعداد مشاهده مقاله: 517 تعداد دریافت فایل اصل مقاله: 316 |